MD908T
D9015Touch screen 15 inch patient monitor 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions,
D9015Touch screen 15 inch patient monitor 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions,
Read More
15” high resolution color TFT display with maximum 13 waveforms
Full touch-screen enables intuitive operation by clicking on the specific parameters
of the waveform in real time, standard configuration includes the navigation knob
Pacemaker detection, electrosurgical interference proof
Defibrillation protection and defibrillation synchronization
SD Card slot enable memory extension for large data storage
USB and serial port enable abundant future upgrades
VGA output and Analog output
OxyCRG available to judge the respiration and circulation function for neonate
Large font display
Arrhythmia and S-T segment analysis
Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
Nurse Call function and bi-directional communication with MFM-CMS central station
Multi language: English/Simplified Chinese/Traditional Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
Electrocardiogram (ECG)
Heartrate (HR)
Pulse Oximetry
SPO2 Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%;
1% to 69% range: ±5%;
Method: Dual wavelength LED
ST-segment
Arrhythmia analysis
Respiration Rate
Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 40 to 240 mmHg
Neonate: 10 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement
Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult: 300mmHg
Pediatric: 240 mmHg;
Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range: 30 to 250 bpm
Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
Input mode | Five-lead ECG input / three-lead ECG input |
Lead selection | I, II, III, aVR, aVL, aVF, V- |
Gain selection | AUTO,0.25X,0.5X,1X,2X,4X |
Operating mode | Diagnostic mode, monitoring mode, operation mode |
Calibration signal | 1mV ±5% |
Protection | The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife. Anti-defibrillation protection. |
Pacemaker at the same time use | Support |
Electrode off instructions | Each electrode (RL excluded) |
Scanning speed | 12.5mm/s, 25 mm/s, 50 mm/s |
Common mode rejection ratio | ≥90dB |
Input impedance | ≥5.0MΩ |
Heartrate (HR)
Measuring range | Adult 30 ~ 300bpm, newborns 30 to 350 bpm |
Resolution | 1 bpm |
Accuracy | < ±5bpm |
Heart rate sensitivity | ≥0.20mVp-p |
Alarm range | 15 to 350 bpm, upper and lower limits |
Alarm indication |
Audible and visual alarm, display the data and parameters flashing display alarm message text prompts, there are three levels of alarm |
Pulse Oximetry
SPO2 Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ±2%;
1% to 69% range: ±5%;
Method: Dual wavelength LED
ST-segment
ST-segment measurement range | -2.0~+2.0mV |
ST-segment measurement accuracy |
Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%, Whichever is greater; Other range: undefined |
Resolution | 0.01mV |
ST-segment update cycle | 10s |
ST segment alarm range | -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable |
Arrhythmia analysis
Arrhythmia types | 13 kinds of (scalable) |
Respiration Rate
Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
Technique: Oscillometric during inflation
Range: Adult/Pediatric: 40 to 240 mmHg
Neonate: 10 to 150 mmHg
Measurement Cycle: < 40 sec. typical
Automatic Measurement
Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
STAT Mode: 5 minutes of continuous readings
Max. Allowable Cuff
Pressure: Adult: 300mmHg
Pediatric: 240 mmHg;
Neonate: 150 mmHg
Resolution: 1 mmHg
Transducer Accuracy: ±2 mmHg or ±2% of reading,
Heart (Pulse) Rate
Range: 30 to 250 bpm
Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
Interface form | External interface |
Range of measurement |
0~10 kPa or (0~75) mmHg |
precision(error) |
(0kPa~5.4kPa) the error is ±0.3kPa、 (5.5kPa~10.0kPa)the error is ±0.7kPa |
Alarm upper limit | 2.1~13.2 kPa |
Alarm lower limit | 0~6.5 kPa |
time | 12s |
EtCO2 | exist |
Unit | kPa / mmHg / % |
Compatibility |
external main stream and side stream are compatible |
IBP technological index |
|
Measured channel | Single way and double way are optional |
Range of measurement |
SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg) MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg) DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg) |
Mean error | ≤±0.4kPa (±3mmHg) |
Range of alarm |
SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg) Lower limit 0kPa~53.1kPa(0mmHg~398mmHg) MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg) Lower limit 0kPa~53.1kPa (0mmHg~398mmHg) DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg) Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg) |
Measured unit | mmHg/kPa |
Specification of sensor |
DPT-248(space) |
Consumables mode | SCW-UTAH-01 |
Standard:
ECG Cable (5 Leads) ...... 1Pcs
SpO2 Cable (Adult) ........ 1Pcs
TEMP Probe (Adult) ....... 1Pcs
NIBP Cuff (Adult) ............ 1Pcs
NIBP Tube(150cm) ......... 1PcsWall mount with basket .... 1pcs
Remote control .................1pcs
Ground Cable ................ 1Pcs
Power Cable ................... 1Pcs
Cleaning Cloth ................ 1Pcs
Options:
ECG Cable (3 Leads)
ECG Alligator Clips (Metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
NIBP Cuff (infant 8 - 14 cm 5/Bag)ECG Alligator Clips (Metal)
SpO2 Cable (Adult hard shell sensor)
SpO2 Cable (Adult Soft shell sensor)
SpO2 Cable (Neonatal soft sensor)
Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
IBP Adapter (2-IBP)
IBP Reusable Interface Cable
IBP Disposable Transducers
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
IBP Adapter (2-IBP)
IBP Reusable Interface Cable
IBP Disposable Transducers
Related items
Hillinton Medical Equipment Co.,Ltd is part of Magina Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Hillinton and all corresponding design marks are trademarks of Hillinton. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.
- Legal notice
- Terms and conditions
- Cookie policy
- Privacy Policy
- Professional organisations
- Careers
- Sitemap
2020© Copyright Shandong Hillinton Medical Equipment Co.,Ltd (Magina Group).